REMEMBER to turn off the power. Follow the steps below to hang yourfan properly;Step 1. Remove two knock-outs from the outlet box to expose the joist.

Page 3

Fig.11SET SCREWSET SCREWOUTLETBOXOUTLETBOXKNOCKOUTFig.8Fig.6Fig.5Fig.9Fig.7Fig.10HANGERBRACKETPLATESTAR WASHERSLOCK WASHERSFLAT WASHERSWOOD SCREWSFLAT

Page 4

WARNING:To avoid possible electrical shock be sure electricity isturned off at the main fuse or breaker box before wiring.Step 1.Insert Receiver into

Page 5 - CONTENTS

After all splices are made, check to makesure there are no loose strands. As anadditional precaution we suggest to securethe plastic wire connectors t

Page 6 - SAFETY FIRST

WARNING! HOOK UP "IN SERIES" ONLY. DO NOT CONNECT NEUTRAL SUPPLY WIREOF ELECTRIC CIRCUIT TO THE TRANSMITTER WALL SWITCH, DAMAGE TO THETRANSM

Page 7

Step 1. Remove 1 of the 2 screws from the bottom of the hanger bracket and loosen the otherone half a turn from the screw head.Step 2. Slide the canop

Page 8 - PACKAGE CONTENTS

8Step 1. Attach the fan blade to the blade bracket using the screwsprovided. Tighten screws securely. Repeat for remaining blades.(Fig. 18).Step 2. Re

Page 9 - BEGIN INSTALLATION

Step 1. Remove the screws from the switch cup plate. Connect the switch cup and fan wire molex connectors, Place the switch cup over the switch cup pl

Page 10 - HANGING THE FAN

A. Buttons:These buttons are used to set the fan speedsas follows;= Low Speed= Medium Speed= High SpeedB.Button:This button turns the fan off.C.

Page 11 - Fig.9Fig.7

Fig 21 Fig 22SUMMER OPERATIONWINTER OPERATIONSpeed settings for warm or cold weather depend on factors such as room size, ceiling height and number

Page 12 - ELECTRICAL CONNECTIONS

Manual design and all elements of manual design are protected by U.S. Federal and/or State Law, including Patent, Trademark and/or Copyright Laws.

Page 13 - Fig.14 Fig.15

Here are some suggestions to help you maintain your fan.1. Because of the fan's matural novement,some connections may becomeloose. Check the supp

Page 14

SYMPTOM Fan Wobble SOLUTION1.NOTE: All blade sets are grouped byweight. Because wood and plasticblades vary in density, the fan maywobble even thoug

Page 15 - FINISHING THE INSTALLATION

SYMPTOM Frequency interferenceSOLUTION1.Turn the power off to your ceiling fan.2.lease use a small size tool to change the frequency setting on the c

Page 16 - ATTACHING THE FAN BLADES

SPECIFICATIONS13These are typical readings Your actual fan may vary. They do not Include amps orwattage used by the light kit.Blade Span Fan Speed Vo

Page 18

Minka-Aire®warrants to the original owner that this fan will be free from defects in material and workmanship for oneyear from the date of purchase, e

Page 19 - WINTER OPERATION

This warranty shall not apply to fans which have been damaged in any way, including improper installation, damage as a result of the removalof the fan

Page 20 - MAINTENANCE

CONTENTS1151W. Bradford Court, Corona CA 92882 For Customer Assistance Call: 1-800-307-3267 SAFETY FIRST 1PACKAGE CONTENTS 2BEGIN INSTALLATION 3HANGIN

Page 21 - TROUBLESHOOTING

1. Before you begin installing the fan, shut power off at the circuit breaker of the fuse box.2. Be cautious! Read all instructions and safety informa

Page 22

WARNINGSUPPORT DIRECTLY FROM BUILDING STRUCTURE.TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR OTHER PERSONAL INJURY. MOUNT FAN DIRECTLY TO THE BUILDIN

Page 23 - SPECIFICATIONS

1. Fan motor/housingass'y2. Canopy3. Switch Cup4. Fan blade5. Coupling cover6. Blade bracket7. Standard 6"downrodassembly8. Minimum 3-1/2&qu

Page 24 - English Verison

BEGIN INSTALLATIONMOUNTING OPTIONSIf there isn't an existing mounting box,then read the following instructions.Shut thepower off at the circuit b

Related models: F539-BCW

Comments to this Manuals

No comments